Effect of cataract surgery incision location and intraocular lens type on ocular aberrations. [Post print]

dc.contributor.authorPesudovs, Konrad
dc.contributor.authorDietze, Holger
dc.contributor.authorStewart, Owen G
dc.contributor.authorNoble, Bruce A
dc.contributor.authorCox, Michael J
dc.date.accessioned2006-08-24T06:45:39Z
dc.date.available2006-08-24T06:45:39Z
dc.date.issued2005-04
dc.description.abstractPURPOSE: To determine whether Hartmann-Shack wavefront sensing detects differences in optical performance in vivo between poly(methyl methacrylate) (PMMA) and foldable acrylic intraocular lenses (IOLs) and between clear corneal and scleral tunnel incisions and whether optical differences are manifested as differences in visual performance. SETTING: Department of Optometry, University of Bradford, West Yorkshire, United Kingdom. METHODS: This study comprised 74 subjects; 17 were phakic with no ocular pathology, 20 had implantation of a Pharmacia 722C PMMA IOL through a scleral tunnel, 21 had implantation of an Alcon AcrySof IOL through a scleral tunnel, and 16 had implantation of an AcrySof IOL through a corneal incision. Visual acuity and contrast sensitivity testing, ocular optical quality measurement using Hartmann-Shack wavefront sensing, and corneal surface measurement with a videokeratoscope were performed in all cases. RESULTS: There were significant differences between groups in the total root-mean-square (RMS) wavefront aberration over a 6.0 mm pupil (F=3.91; degrees of freedom=3,70; P<.05) mediated at the 4th-order RMS, specifically spherical and tetrafoil aberrations. The PMMA-scleral group had the least aberrations and the AcrySof-corneal group the most. For a 3.5 mm diameter pupil, the total higher-order RMS wavefront aberration was not significantly different between the groups (P>.05). There were no differences between groups in corneal shape, visual acuity, or contrast sensitivity. CONCLUSIONS: Implantation of the spherical PMMA IOL led to a slight reduction in total wavefront aberration compared to phakic eyes. AcrySof IOLs induced more aberrations, especially spherical aberration. Corneal-based incisions for IOL implantation compounded this increase. Studies of the optical performance of IOLs in vivo should use wavefront sensing as the main outcome measure rather than visual measures, which are readily confounded by multiple factors.en
dc.format.extent201400 bytes
dc.format.mimetypeapplication/pdf
dc.identifier.citationPesudovs K. Dietze H. Stewart O G. Noble B A. Cox MJ. 2005 Effect of cataract surgery incision location and intraocular lens type on ocular aberrations. 'Journal of cataract and refractive surgery' Vol 31, No 4, 725-34en
dc.identifier.issn0886-3350
dc.identifier.urihttp://hdl.handle.net/2328/1142
dc.language.isoen
dc.oaire.license.condition.licenseIn Copyright
dc.publisherElsevieren
dc.subjectAcrylic Resinsen
dc.subjectContrast Sensitivityen
dc.subjectCorneaen
dc.subjectCorneal Topographyen
dc.subjectLens Implantation, Intraocularen
dc.subjectLenses, Intraocularen
dc.subjectPhacoemulsificationen
dc.subjectPolymethyl Methacrylateen
dc.subjectRefraction, Ocularen
dc.subjectRefractive Errorsen
dc.subjectScleraen
dc.subjectVisual Acuityen
dc.subject.otherAustralian Research Classification 321016 Ophthalmology and Vision Scienceen
dc.titleEffect of cataract surgery incision location and intraocular lens type on ocular aberrations. [Post print]en
dc.typePreprinten
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
IOL aberrations jcrs revised.pdf
Size:
196.68 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.45 KB
Format:
Item-specific license agreed upon to submission
Description: